Carrier 48fc 15 ton.

Check out our list of family-friendly international carriers so you pick the right airline for your family's next flight. We'll tell you who offers infant and children's meals, spe...

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Carrier rooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: •Single circuit, single stage cooling model on 6 ton •Single circuit, 2-stage cooling mod-els are available from 7.5 to 10 ton. •Dual circuit 2-stage cooling stage models are available from 7.5 to 15 ton.6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...Choosing among a broad range of air conditioner brands can be overwhelming. So we've narrowed it down to two brands, YORK® and Carrier, to help you decide. Expert Advice On Improvi...Nominal Capacity (Ton): 15 Ton. Efficiency: Standard. Voltage (Phase): 208/230 V 3-Phase. California Prop 65: False. Capacity Modulation: 2-Stage. Category: Packaged …Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor)

Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. 48GC units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance. 4.Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...

Carrier Puerto Rico - Air Conditioning

View and Download Carrier WeatherMaker 48FC04-07 installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puron R-410A Refrigerant. ... The W7220 controller does not actually control the fan On single phase 48FC 3 to 5 ton units, if reduced the heat- speed or the heat output of the unit, and only ...6 to 23 Nominal Tons. 50LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have the some of the industry’s highest IEERs available. The multi stage cooling compressor allows for added comfort, energy savings and humidity control.6 to 23 Nominal Tons. 50LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have the some of the industry’s highest IEERs available. The multi stage cooling compressor allows for added comfort, energy savings and humidity control.Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.

Carrier

15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available ...

48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged …48 50FC 8 16 01PD Carrier Nominal 10 Ton 11 2 EER Package RTU Cooling Only Two Stage 208 3 siglers mw link id 10646 ||| Product Data WeatherMaker Single Packaged Rooftop 7.5 to 15 Nominal Tons 2023 Carrier 48/50FC**08, 09, 12, 14, 16 48FC: Single-Package Gas Heating/Electric Cooling Rooftop Units 50FC: Electric Cooling Rooftop … Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ... 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerCarrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;

Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …This manual is also suitable for: View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A Refrigerant. WeatherMaker Puron 48FC 04 Series air conditioner pdf manual download. 48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU Restore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480329-01 Printed in U.S.A. Form 48FC-8-14-01SI Pg CL-2 8-21 Replaces: New.With so many cell phone carriers to choose from, it can be difficult to determine which one is the best fit for you. The first step in finding the right cell phone carrier is to ev...InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...

Field Convertible airflow (3−12.5 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 12.5 ton models require a simple supply air duct cover to field convert from factory vertical to horizontal. Provisions for thru−the−bottom power entry capability as standard

20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels. 48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …AERO® Indoor/Outdoor Small Air Handler. 39S. Construction: Compact single/double-wall. Application: Indoor, Outdoor. Airflow Range (Cfm): 400 - 8,500. Documents Details. Carrier offers custom, compact, single wall and double wall air handlers and air handling units to meet the HVAC needs of commercial customers.Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...

Most of Carrier’s 3−12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. ... SEER up to 15.6, EER up to 13.0 IEER’s up to 14.0 with single speed indoor fan motor, and up to 16.0 with SAV (Staged Air Volume) 2−speed/VFD

Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.

The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480371-01 Printed in U.S.A. Form 48FC-16-01SI Rev. A Pg 1 7-22 Replaces: New. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. •Carrier exclusive Ultra Low NOx gas heat emissions burner box and heat exchanger design that provides 14 nanograms/joule (ng/j) operation. •Reliable fixed speed scroll compres-sor on 3-5 ton sizes •Upgraded unit control board with intuitive indoor fan adjustment •Reliable copper tube/aluminum fin condenser coil with 5/ 16-in. tubingView and Download Carrier WeatherMaker 48FC04-07 installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puron R-410A Refrigerant. ... The W7220 controller does not actually control the fan On single phase 48FC 3 to 5 ton units, if reduced the heat- speed or the heat output of the unit, and only ...Authorities recovered 172 gold bars scattered on the runway. By clicking "TRY IT", I agree to receive newsletters and promotions from Money and its partners. I agree to Money's Ter...Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = 460/3/600 = Electromechanical Controls caCarrierPerformance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single …Supply Width 15.52 Return Length 37.921 Return Width 15.799 RW RL SW SL CW CL Table 5. Curb matrix Type Trane Lennox Carrier Bryant JCI/York ICP Heil Day and Nigh Goodman Daikin Older Voyager Gas/Electric GCC036-060 ZGB 036-060 48DJ 004-00, 48GJ 006 48HC 004-006, 48HE 004-006 48HJ 004-006, 48KC 004-006 48LJ 004-006, …3 UNIT ARRANGEMENT AND ACCESS General Figures 1 and 2 show the general unit arrangement and access locations. Fig. 1 — Access Panels and Components, Front Fig. 2 — Typical Access Panel Locations, Rear Routine Maintenance

04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerDrawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...CarrierInstagram:https://instagram. ip190 pill whitehamilton county gis mappingla ruleta sikeston mocorelle dishes lead paint Do not use R-22 service equipment or components on R-410A refrigerant equipment. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480274-01 Printed in U.S.A. Form 48A-21SI Pg 1 11-21 Replaces: 48A-20SI.access it. Carrier r ooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: † Single cooling stage models are available from 6 to 10 ton. † 2-stage cooling stage models are available from 7.5 to 15 ton. † EERs up to 11.1 † IEERs up to 11.7 with single speed wawa hagerstown mdkuykendall border collies All 10 ton units and 6 to 8.5 ton high efficiency units offer variable speed direct drive motors. Direct Drive Plenum Fan The following units are equipped with a direct drive plenum fan design (all 10 ton units, 6 (074) to 8.5 ton high efficiency units, and optional on 7.5 (092) to 8.5 ton standard efficiency units). Plenum fan designView and Download Carrier 48HC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R-410A) Refrigerant Sizes: 04, 05, 06. 48HC air conditioner pdf manual download. Also for: 48hc series, 48hc-a04, 48hc-a05, 48hc-a06. julia's bakery High Altitude Conversion Kit (LP), 3-15 Ton. Item. CRLPELEV003A00. Please Login or Register to view pricing and inventory. Skip to the end of the images gallery ... CARRIER MODELS Check positions 7-8 on unit data plate for unit size. MODEL / UNIT SIZES / NOMINAL TONS 48FC / 04-07 / 3-6 48GC / 04-06 / 3-5 48TC / 08-16 / 7.5-15 48HC / 07 …Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. 48GC units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance. 4.